Monday, September 14, 2015

High Output Panel Radiators Designed For Comfort


Smith’s Environmental Decoro Design Panel Radiators combine the comfort of radiant heat with an elegant contemporary design. These attractive radiators have been providing unsurpassed comfort and e fficiency in European homes for more than 40 years. Because they are extremely versatile they can be used as a primary heating system, a supplement to a radiant floor system, or in conjunction with traditional heating sources.

Features

  • Space Saving Design 
  • Quiet, Comfortable Heating 
  • Efficient Heat Transfer 
  • Scratch, Dent And Corrosion Resistant 
  • Individual Room Temperature Control 
  • Available In A Variety Of Heights And Lengths 
  • 10 Year Warranty

Learn more about Smith's Environmental Products on our website: http://www.emersonswan.com/manufacturers-products/smiths-environmental.html

Monday, September 7, 2015

Taco $25 Circulator Rebate


IT DOESN’T GET ANY HOTTER THAN THIS!

Get a $25 rebate on the following Taco hot water solutions. Buy as many as you want. You get a $25 rebate on each item, your customers get instant hot water and savings.

Qualifying Products
  • Taco Hot-Link
  • Taco SmartPlus
  • Taco Genie

Purchase any number of Taco Hot-Link, SmartPlus or TacoGenie between September 1, 2015 and November 30, 2015 from a participating Taco distributor and receive up to a $25 rebate for each product purchased via mail-in fulfillment. Click here for the rebate form.

Learn more about Taco products on our website: http://www.emersonswan.com/manufacturers-products/taco-dp.html

Tuesday, September 1, 2015

HTP Introduces the Enduro Ti

HTP has announced a major new addition to their industry leading boiler line -- the Enduro Ti commercial condensing boiler. The new Enduro Ti is a large mass condensing boiler manufactured out of stainless steel AISI 316Ti. It is equipped with an extremely efficient hyper-jet combustion system with a patented modulating inward firing burner. This high mass fire tube design promotes improved heat transfer when used with its stainless steel and titanium based three-pass heat exchanger. This durable unit is built to last a lifetime. The unit is up to 93% thermal efficient, with up to a 10:1 turndown ratio. It is available in two BTU sizes: 750,000 and 1,000,000.


Learn more about HTP products on our website: http://www.emersonswan.com/manufacturers-products/heat-transfer-products.html

Monday, August 17, 2015

The Comfort Of Radiant Without The Mechanical Room

Enjoy the simplicity of electric indoor floor heating and turn cold concrete floors into a welcoming comfort. SlabHeat, by Watts Radiant, is ideal for basements, garages, sunrooms, offices, warehouses, and countless other interior slab projects.

Operating a SlabHeat system couldn't be easier. Simply connect a SunStat Control or Relay directly to the SlabHeat cable with either 120 or 240 VAC line power. Each SunStat automatically turns the system on and off when needed.

Picture: 1. Polyurethane outer jacket 2. Foil shield 3. Braided copper ground plane 4. High temp ETFE element covering 5. Oxygen-free copper alloy heating elements

What Is Electric Slab Heating?
SlabHeat is an electric heating cable used solely for indoor applications. It is perfect for new construction or remodeling projects.

Installation 
  • Can be installed in a slab cap, a new slab or over an existing slab. 
  • Cable can be spaced depending on your warming needs. 
Technical 
  • Single point connection.
  • Available in 120VAC and 240VAC

Learn more about Watts Radiant on our website: http://www.emersonswan.com/manufacturers-products/watts-radiant.html

Monday, August 10, 2015

Reducing Boiler Noise

What causes boiler noise?

Boiler noise is usually the result of limescale deposition within the heat exchanger of a boiler. This condition is worsened if magnetite is also present in the system, as this combines with the limescale to form a much harder deposit. Other sediment-forming debris such as sand and brick dust entering the system during installation can also become part of the hardened deposit. Local water conditions also play an important part, particularly the scale-forming solids dissolved in the supply water.

Boiler noise is directly related to the rapid condensation or implosion of steam in water. Localized boiling develops on the surface of the deposit, and small steam bubbles are created that make a rattling noise as they leave the surface and travel around the system.

When installed into existing systems, new boilers can become excessively fouled soon afterwards by oxide sludge present in the system water. Replacing a boiler can disturb soft sludge and loosen sediment in other parts of the system, causing it to be transported by the system water and re-deposited in the new heat exchanger.

The same phenomenon can occur as a result of circulator replacement if flow rates change. The risk of sediment and sludge deposition in new boilers can be avoided by cleaning the system as part of the installation process.

What should be done?

Fernox DS40 System Cleaner selectively dissolves oxide sludge without attacking metals commonly found in central heating systems. However this acid-based cleaner should only be used in new installations.

Older systems that have been untreated for periods of time may have existing leaks that are temporarily plugged with corrosion debris. Installations with a history of radiator corrosion failures should not be acid cleansed, as other radiators are likely to have deep corrosion pits or complete perforations.

Older installations can be substantially improved, however, by dispersing the sludge with Fernox Cleaner F3 or Powerflushing Cleaner F5 , followed by power flushing with plain water.

After removing all soft sludge from older installations separate boiler de-scaling may be helpful. In order to do this, the radiators should be isolated after which the system can be descaled over a period - up to 24 hours.

This should be followed by rinsing with plain water and neutralizing to passivate the surfaces within the system. Fernox DS40 System Cleaner and Neutraliser can be used in this process.

After cleaning, the entire system should be re-treated using Fernox Protector F1 to eliminate the causes of boiler noise.

Learn more about Fernox system treatment on our website: http://www.emersonswan.com/manufacturers-products/fernox.html

Monday, August 3, 2015

Premium Reflective Bubble Insulation That Can Be Used Virtually Anywhere!

Space Age insulation, by Insulation Solutions, is rolled, easy-to-use insulation designed to create a more comfortable living/working space and help cut down on energy costs. Adding a radiant barrier to existing insulation can boost the overall R-value of the building by preventing radiant heat gain. Conversely, in the winter, radiant barriers assist with keeping the space warm by reducing heat loss. Unlike mass insulation, Space Age contains no itchy fibers and cuts easily with a knife or scissors. Available in double bubble and single bubble configurations, Space Age is manufactured in convenient sizes so waste is minimized and installation is simplified.

Common applications include attics, walls, HVAC ducts, water heaters, pole barns, metal buildings, marine/RV, radiant heating and crawl spaces. Depending on your given application(s), Space Age is available with single-sided or double-sided reflectivity.

Learn more about Insulation Solutions products on our website: http://www.emersonswan.com/manufacturers-products/insulation-solutions.html

Monday, July 27, 2015

3/4" Press Connection Added To The Taco Zone Sentry Line-Up

Taco is pleased to announce the addition of a 3/4" press connection to the Zone Sentry line-up.

A press connection has been the most requested addition to the Zone Sentry line up for some time and it has arrived. This connection style is a rapidly growing choice as a method of installation for many of today's contractors. For those contractors preferring press connections, the press Zone Sentry eliminates the added time, cost and potential leak created when installing press adapters to a threaded valve.

In the case of a sweat valve, installation time is also greatly reduced and it does not require the use of a torch. This can be a challenge in some locations or particular installations such as when a permit is required for use of an open flame.

Model Numbers
Z075P2-1: Normally Closed 3/4" Press Connection
V075P2A1ZB024Q4A1: Normally Open 3/4" Press Connections

Learn more about Taco products on our website: http://www.emersonswan.com/manufacturers-products/taco-dp.html